(734) 327 4079 info@ansight.com
AnSight’s Solutions for COVID-19

Optimum Placement for Air-Cooled Chillers

ASHRAE Journal, January 2016

Author:

Kishor Khankari

Abstract:

Air-cooled chillers are becoming a primary choice for heat rejection in the regions of the short supply of water. The performance of the air cooled condensers/chillers can degrade under high ambient temperature and windy conditions. Several factors including the wind speed, wind direction, spacing between the chillers, and distance from the adjacent building can affect the performance of air-cooled chillers. This study with the help of Computational Fluid Dynamics (CFD) analyses evaluates the impact of these parameters on the airflow patterns, dispersion of the hot exhaust plumes from the chillers, and on the air temperature distribution at chiller air intakes. The extent of hot exhaust plume recirculation into the chillers intakes is estimated in terms of the average intake air temperature. These analyses indicate increasing wind speeds increase the recirculation of exhaust plumes into the chiller air intakes. Orienting the chillers perpendicular to the prevailing wind direction can promote the cascading effect of the hot plume recirculation. The spacing between the chillers has a larger impact on the recirculation of hot exhaust plumes than the distance between the building and the chillers. Reducing the spacing between the chillers can significantly increase the recirculation of hot exhaust plumes and resulting intake air temperature. This study further indicates that placing the chillers too close to the building can promote the recirculation of hot plumes back into the chiller air intakes. However, moving the chillers beyond a certain distance from the adjacent building would not yield any significant reduction in the intake air temperatures.

Fill the following form to download






    About the author

    Dr. Kishor Khankari

    ASHRAE Fellow, ASHRAE Distinguished Lecturer

    Dr Kishor Khankari is the founder of AnSight LLC. As a specialist in Computational Fluid Dynamics (CFD), his passion for solving engineering problems and providing sound scientific solutions has led to innovations and optimized designs in the industry.

    A noted expert in his field, he has a Ph.D. from the University of Minnesota and has published in several technical journals and trade magazines. As a well sought-after speaker Dr. Khankari makes regular presentations in various technical conferences and professional meetings worldwide.

    Recent Posts

    Ventilation Guidance for Residential Kitchen with Gas Stove

    Recently the residential gas stoves were in the News due to the generation of pollutants during their operation. Cooking activities as well as the combustion of natural gas through gas stove burners produce several indoor pollutants. Exhausting these pollutants from...

    CFD Analysis of Residential Kitchen Ventilation with Gas Stove

    Proper ventilation of the kitchen is essential to reduce the occupant exposure to various pollutants generated during the cooking and the combustion of natural gas through the gas stove burners. Several parameters related to the design and operation can affect the...

    CFD Analysis of Demand Control Ventilation for Laboratories

    What is Demand Control Ventilation (DCV)? Often high air change rates per hour (ACH) are specified for laboratories to meet the goal of ventilation. The ACH numbers specified are mostly consensuses based on simplistic approaches of perfect mixing of contaminants with...