(734) 327 4079 info@ansight.com
AnSight’s Solutions for COVID-19

Dynamics of Semi Unidirectional Airflow

ASHRAE Conference Paper for ASHRAE Winter Conference, Chicago, IL

Author:

Dr. Kishor Khankari

Abstract:

Perfectly unidirectional (laminar) flows are rare. Such flows can be attempted either by supplying the air through HEPA filters covering the entire ceiling or by placing restraining panels around the array of supply (laminar) diffusers. In most other cases the flows are “semi unidirectional” – unidirectional only in the core of the supply air stream and recirculating/mixing in the other locations. This study analyzes behavior of such semi unidirectional flows under isothermal and non-isothermal conditions. A CFD model of a virtual test chamber is developed to study the effect of supply airflow rates/discharge velocity on the airflow patterns, velocity, and temperature distribution. A total of four supply airflow rates ranging from 200 cfm (94.4 lps) to 800 cfm (377.6 lps) are analyzed. Non-isothermal analyses are performed for two different locations of sensible heat sources – one with the heat source on a table and the other with heat sources near the ceiling. This study indicates that under isothermal conditions the discharge velocity (flow rate) has little impact on the flow behavior of the supply air jet. For the conditions analyzed, the velocity of the isothermal downward air jet decreases (and becomes non-unidirectional) after traveling about 60 percent of the distance from the discharge. However, in the case of non-isothermal conditions the discharge velocity can significantly affect the directionality of the flow. When a heat source was placed on the table and when the cooling capacity of the supply air jet was four times the cooling load, the air jet could overcome the upward buoyant force of the hot air. When heat sources were placed near the ceiling, the hot air surrounding the heat sources entrained into the downward moving jet causing acceleration in the centerline velocity, which showed to decrease with increasing airflow rate. Interestingly such acceleration was lowest for the lowest supply airflow rate. This study further indicates that for non-isothermal conditions Archimedes Number can be a good initial indicator for estimating the directionality of the supply air jet. This number should be smaller than 0.2 for the cold air jet to travel further without substantially losing its unidirectional behavior.

Fill the following form to download






    About the author

    Dr. Kishor Khankari

    ASHRAE Fellow, ASHRAE Distinguished Lecturer

    Dr Kishor Khankari is the founder of AnSight LLC. As a specialist in Computational Fluid Dynamics (CFD), his passion for solving engineering problems and providing sound scientific solutions has led to innovations and optimized designs in the industry.

    A noted expert in his field, he has a Ph.D. from the University of Minnesota and has published in several technical journals and trade magazines. As a well sought-after speaker Dr. Khankari makes regular presentations in various technical conferences and professional meetings worldwide.

    Recent Posts

    Ventilation Guidance for Residential Kitchen with Gas Stove

    Recently the residential gas stoves were in the News due to the generation of pollutants during their operation. Cooking activities as well as the combustion of natural gas through gas stove burners produce several indoor pollutants. Exhausting these pollutants from...

    CFD Analysis of Residential Kitchen Ventilation with Gas Stove

    Proper ventilation of the kitchen is essential to reduce the occupant exposure to various pollutants generated during the cooking and the combustion of natural gas through the gas stove burners. Several parameters related to the design and operation can affect the...

    CFD Analysis of Demand Control Ventilation for Laboratories

    What is Demand Control Ventilation (DCV)? Often high air change rates per hour (ACH) are specified for laboratories to meet the goal of ventilation. The ACH numbers specified are mostly consensuses based on simplistic approaches of perfect mixing of contaminants with...

    CFD Analysis Evaluates Efficacy of Reactive Air Cleaning Technology

    What is reactive air cleaning? Reactive air cleaning involves the release of reactive agents in the room to actively mitigate airborne pathogens and other pollutants. Unlike traditional dilution ventilation in which the concentration of the airborne pathogens in the...