CFD Analysis of Airflow Patterns and Probability of Infection in Indoor Spaces – A Concept of Aerodynamic Containment

ASHRAE Annual Conference Phoenix, AZ, 2021

Author:

Kishor Khankari

Abstract:

The purpose of a ventilation system for indoor spaces is to create a safe environment for the occupants by diluting the concentration levels of hazardous contaminants and to minimize the risk of infection due to spread of airborne pathogens. The effectiveness of ventilation system depends on several inter related factors including the supply airflow rate, number and locations of supply diffusers, and number and locations of return grilles. With the help of Computational Fluid Dynamics (CFD) analyses, this study systematically evaluates the impact of three different HVAC configurations on the airflow patterns, distribution of contaminant, and the risk of infection in a small office space with two cubicles. The HVAC configuration with a single supply and a single return can create adverse airflow patterns which can promote spread of contaminants and increase the risk of infection farther from the source. When an additional supply diffuser is introduced with the same single return, the zone of high risk of infection remained in the vicinity of the source. However, the overall risk of infection in the space remained the same. Addition of another return created aerodynamic containment zones in the space which provided easy path for the contaminated air to leave the space and reduced the overall risk of infection. Since the location of an infected individual is not known a priori, the aerodynamic containment with distributed supply and distributed return can be the best strategy for reducing the probability of infection in indoor spaces. These studies demonstrate that CFD analyses can help in identifying the potential risk of high infection due to poor airflow distribution into a space and can provide valuable insights for developing appropriate mitigation strategies to create safe indoor environment.

Fill the following form to download






    About the author

    Dr. Kishor Khankari

    ASHRAE Fellow, ASHRAE Distinguished Lecturer

    Dr Kishor Khankari is the founder of AnSight LLC. As a specialist in Computational Fluid Dynamics (CFD), his passion for solving engineering problems and providing sound scientific solutions has led to innovations and optimized designs in the industry.

    A noted expert in his field, he has a Ph.D. from the University of Minnesota and has published in several technical journals and trade magazines. As a well sought-after speaker Dr. Khankari makes regular presentations in various technical conferences and professional meetings worldwide.

    Recent Posts

    Ventilation Guidance for Residential Kitchen with Gas Stove

    Recently the residential gas stoves were in the News due to the generation of pollutants during their operation. Cooking activities as well as the combustion of natural gas through gas stove burners produce several indoor pollutants. Exhausting these pollutants from...

    CFD Analysis of Residential Kitchen Ventilation with Gas Stove

    Proper ventilation of the kitchen is essential to reduce the occupant exposure to various pollutants generated during the cooking and the combustion of natural gas through the gas stove burners. Several parameters related to the design and operation can affect the...

    CFD Analysis of Demand Control Ventilation for Laboratories

    What is Demand Control Ventilation (DCV)? Often high air change rates per hour (ACH) are specified for laboratories to meet the goal of ventilation. The ACH numbers specified are mostly consensuses based on simplistic approaches of perfect mixing of contaminants with...

    CFD Analysis Evaluates Efficacy of Reactive Air Cleaning Technology

    What is reactive air cleaning? Reactive air cleaning involves the release of reactive agents in the room to actively mitigate airborne pathogens and other pollutants. Unlike traditional dilution ventilation in which the concentration of the airborne pathogens in the...