Analysis of Supply Airflow Rate on the Performance of Radiant Cooling Systems

ASHRAE Winter Conference, Orlando, FL, 2016

Author:

Kishor Khankari

Abstract:

Radiant cooling systems can potentially be more energy efficient than the traditional all air HVAC systems partly due to their low supply air requirements. This paper with the help of Computational Fluid Dynamics (CFD) analysis compares the cooling performance of a traditional all air system with the radiant cooling systems for a typical perimeter office. The effect of supply airflow rate on the cooling performance of both radiant floor and radiant ceiling systems is evaluated. The cooling performance is evaluated in terms of three-dimensional airflow patterns, temperature distribution, thermal comfort of occupants, and resulting cooling capacity of the radiant surfaces. These analyses indicate radiant cooling systems can provide comparable thermal comfort for occupants at much reduced airflow rates than the traditional all air system. However, the location of the radiant surface and associated supply airflow rates can significantly affect the thermal comfort and cooling capacity of the radiant systems. The radiant floor system may require higher airflow rate than the radiant ceiling system to provide comparable thermal comfort. However, increasing the airflow rate can significantly reduce the cooling capacity of the radiant floors than the radiant ceilings. Low airflow rates with radiant floor can create hot zones whereas high airflow rates with radiant ceiling can create cold zones for the occupants. Further the supply airflow rate can significantly affect the relative distribution between the convective and radiative heat transfer components of the radiant floors than the radiant ceilings. This study concludes that the radiant ceiling with low supply airflow rate can provide better thermal comfort and higher cooling capacity, and therefore, a better option for cooling perimeter offices than radiant floors. It is noted that CFD can be an effective tool in minimizing HVAC design risks and gaining valuable insights which can help in optimizing the design of radiant cooling systems.

Fill the following form to download






    About the author

    Dr. Kishor Khankari

    ASHRAE Fellow, ASHRAE Distinguished Lecturer

    Dr Kishor Khankari is the founder of AnSight LLC. As a specialist in Computational Fluid Dynamics (CFD), his passion for solving engineering problems and providing sound scientific solutions has led to innovations and optimized designs in the industry.

    A noted expert in his field, he has a Ph.D. from the University of Minnesota and has published in several technical journals and trade magazines. As a well sought-after speaker Dr. Khankari makes regular presentations in various technical conferences and professional meetings worldwide.

    Recent Posts

    Ventilation Guidance for Residential Kitchen with Gas Stove

    Recently the residential gas stoves were in the News due to the generation of pollutants during their operation. Cooking activities as well as the combustion of natural gas through gas stove burners produce several indoor pollutants. Exhausting these pollutants from...

    CFD Analysis of Residential Kitchen Ventilation with Gas Stove

    Proper ventilation of the kitchen is essential to reduce the occupant exposure to various pollutants generated during the cooking and the combustion of natural gas through the gas stove burners. Several parameters related to the design and operation can affect the...

    CFD Analysis of Demand Control Ventilation for Laboratories

    What is Demand Control Ventilation (DCV)? Often high air change rates per hour (ACH) are specified for laboratories to meet the goal of ventilation. The ACH numbers specified are mostly consensuses based on simplistic approaches of perfect mixing of contaminants with...

    CFD Analysis Evaluates Efficacy of Reactive Air Cleaning Technology

    What is reactive air cleaning? Reactive air cleaning involves the release of reactive agents in the room to actively mitigate airborne pathogens and other pollutants. Unlike traditional dilution ventilation in which the concentration of the airborne pathogens in the...