Analysis of displacement ventilation for hospital patient room

ASHRAE Winter Conference, Atlanta, GA, 2019

Author:

Kishor Khankari

Abstract:

A comparative CFD analysis of overhead supply and displacement ventilation system for a typical hospital patient room indicates that for identical cooling loads the displacement ventilation system can provide relatively better thermal comfort and indoor air quality in the occupied zone. The overhead supply system forms recirculating airflow patterns which cause the airborne particles released from the patient’s face to get entrained back into the supply air stream and spread into the entire room. Whereas in the case of displacement system the thermal buoyancy forces create layered stratified temperature distribution causing predominantly horizontal and vertical airflow patterns which keep these particles afloat near the ceiling and create relatively cleaner environment. The analysis of displacement ventilation system further indicates that the supply airflow rate of 4 ACH can create thermal neutral environment in the occupied zone and provide the optimum thermal comfort for the occupants. Also moving the exhaust grille over the patient’s head can create least resistive flowpath for airborne pathogens to escape from the room and avoid spread along the ceiling.

Fill the following form to download






    About the author

    Dr. Kishor Khankari

    ASHRAE Fellow, ASHRAE Distinguished Lecturer

    Dr Kishor Khankari is the founder of AnSight LLC. As a specialist in Computational Fluid Dynamics (CFD), his passion for solving engineering problems and providing sound scientific solutions has led to innovations and optimized designs in the industry.

    A noted expert in his field, he has a Ph.D. from the University of Minnesota and has published in several technical journals and trade magazines. As a well sought-after speaker Dr. Khankari makes regular presentations in various technical conferences and professional meetings worldwide.

    Recent Posts

    Ventilation Guidance for Residential Kitchen with Gas Stove

    Recently the residential gas stoves were in the News due to the generation of pollutants during their operation. Cooking activities as well as the combustion of natural gas through gas stove burners produce several indoor pollutants. Exhausting these pollutants from...

    CFD Analysis of Residential Kitchen Ventilation with Gas Stove

    Proper ventilation of the kitchen is essential to reduce the occupant exposure to various pollutants generated during the cooking and the combustion of natural gas through the gas stove burners. Several parameters related to the design and operation can affect the...

    CFD Analysis of Demand Control Ventilation for Laboratories

    What is Demand Control Ventilation (DCV)? Often high air change rates per hour (ACH) are specified for laboratories to meet the goal of ventilation. The ACH numbers specified are mostly consensuses based on simplistic approaches of perfect mixing of contaminants with...

    CFD Analysis Evaluates Efficacy of Reactive Air Cleaning Technology

    What is reactive air cleaning? Reactive air cleaning involves the release of reactive agents in the room to actively mitigate airborne pathogens and other pollutants. Unlike traditional dilution ventilation in which the concentration of the airborne pathogens in the...