(734) 327 4079 info@ansight.com
AnSight’s Solutions for COVID-19

Air Change Rate Analysis for a Minienvironment Cleanroom

ASHRAE Journal, August 2017

Author:

Kishor Khankari

Abstract:

Mini-environment cleanrooms are commonly employed in the semi-conductor and pharmaceutical industries to create isolated spaces within a cleanroom to provide better control on the cleanliness and operation of the processes. Mini-environments isolate products and operators from each other to avoid any cross contamination. The required airflow to maintain certain level of cleanliness for mini-environment is much less than that of an equivalent large cleanroom. This paper with the help of a virtual cleanroom setup developed using Computational Fluid Dynamics (CFD) simulations describes the impact of reduced supply airflow rates and the location of supply diffuser on the airflow patterns and resulting distribution of particle concentration in the mini-environment cleanroom. These analyses provide valuable insights into the operation of the mini-environment cleanroom and indicate that reduced airflow rates have a little impact on the airflow patterns and particle distribution within the mini-environment chamber. Reduced airflow rates can make the surrounding room dirtier, however, the location of supply air diffusers in the room can significantly affect the airflow patterns and resulting particle distribution in the room. This study demonstrates CFD analysis can be a valuable tool in gaining insights into the design and operation of the mini-environment cleanrooms.

Fill the following form to download






    About the author

    Dr. Kishor Khankari

    ASHRAE Fellow, ASHRAE Distinguished Lecturer

    Dr Kishor Khankari is the founder of AnSight LLC. As a specialist in Computational Fluid Dynamics (CFD), his passion for solving engineering problems and providing sound scientific solutions has led to innovations and optimized designs in the industry.

    A noted expert in his field, he has a Ph.D. from the University of Minnesota and has published in several technical journals and trade magazines. As a well sought-after speaker Dr. Khankari makes regular presentations in various technical conferences and professional meetings worldwide.

    Recent Posts

    Ventilation Guidance for Residential Kitchen with Gas Stove

    Recently the residential gas stoves were in the News due to the generation of pollutants during their operation. Cooking activities as well as the combustion of natural gas through gas stove burners produce several indoor pollutants. Exhausting these pollutants from...

    CFD Analysis of Residential Kitchen Ventilation with Gas Stove

    Proper ventilation of the kitchen is essential to reduce the occupant exposure to various pollutants generated during the cooking and the combustion of natural gas through the gas stove burners. Several parameters related to the design and operation can affect the...

    CFD Analysis of Demand Control Ventilation for Laboratories

    What is Demand Control Ventilation (DCV)? Often high air change rates per hour (ACH) are specified for laboratories to meet the goal of ventilation. The ACH numbers specified are mostly consensuses based on simplistic approaches of perfect mixing of contaminants with...

    CFD Analysis Evaluates Efficacy of Reactive Air Cleaning Technology

    What is reactive air cleaning? Reactive air cleaning involves the release of reactive agents in the room to actively mitigate airborne pathogens and other pollutants. Unlike traditional dilution ventilation in which the concentration of the airborne pathogens in the...